Brand Name : CITY
Model Number : SR-M-MC MICROCEL CF ABU01-U0W
Place of Origin : UK
MOQ : 1
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 3000pcs/Month
Delivery Time : 3-5Workingdays
Packaging Details : Box
Price : Negotiable
Range of working temperature : -40~+50℃
Recommended storage temperature : 0~20℃
Working pressure range : Atmospheric pressure ± 10%
Operating humidity range : 15 - 90% RH without condensation
Expected service life : 2 years in air
Long term output drift : <5% signal loss per year
SR-M-MC MICROCEL CF ABU01-U0W Gas Sensor 1500 ppm Carbon Monoxide CO Gas Sensor
CITY are designed to operate in a variety of environments and harsh conditions. However, it is important to avoid exposure to high concentrations of solvent vapors when storing, loading the instrument, and working.
When using the sensor on a printed circuit board (PCB), a degreaser should be used before mounting the sensor. Do not stick directly on or near the CiTiceL as the solvent may cause the plastic to crack.
Specification Sheet:
Working principle | Three-electrode electrochemistry |
Measuring range | 0-500 ppm CO |
Overload | 1500 ppm CO |
Filter | Reduce the TLV level of interfering gases |
Sensitivity | 0.045 ± 0.01 μA/ppm |
T50 response time | <10 seconds at 20°C |
Typical T90 response time | 15-20 seconds |
Baseline shift (clean air) | -4~+2 ppm CO equivalent |
Zero offset | (+20°C~ +40°C) |
Gas | Use concentration (ppm) | MICROceL CF (ppm CO) |
H 2 S | 15 | < 0.5 |
SO 2 | 5 | ± 0.1 |
NO | 35 | <6 |
NO 2 | 20 | ± 1 |
H 2 | 100 | < 40 |
C 2 H 5 OH | 200 | ± 1 |
![]() |
SR-M-MC MICROCEL CF ABU01-U0W Gas Sensor 1500 ppm Carbon Monoxide CO Gas Sensor Images |