8413660 0–100 L/min Minute Ventilation Repetitive Exhalation Valve for Ventilator with Oxygen Concentration

Model Number : 8413660

Place of Origin : Germany

MOQ : 1pcs

Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram

Supply Ability : 5000pcs

Delivery Time : 5-8 work days

Packaging Details : Standard packaging

Flow Acceleration : 5–200 mbar/s

Oxygen Concentration : 21–100 vol.%

Trigger Sensitivity : 1–15 L/min

Minute Ventilation : 0–100 L/min

Contact Now

8413660 Repetitive Exhalation Valve Of The Ventilator


Working Principle:

The expiratory valve controls the discharge of exhaled gas during ventilator operation, ensuring smooth exhalation while preventing external air from flowing back into the ventilator circuit. It maintains normal pressure and gas flow direction in the respiratory loop.

Material:

Made of medical-grade plastic or metal, featuring excellent biocompatibility, corrosion resistance, and durability to meet medical environment requirements.

Connection Method:

Designed with standard interfaces for connecting to ventilator breathing circuits and the main unit, ensuring tight and airtight connections. Common methods include threaded or snap-fit connections.

Performance Characteristics:

  • Sealability: Effectively prevents gas backflow during exhalation.
  • Expiratory Resistance: Moderate resistance to avoid hindering patient exhalation, while maintaining pressure stability in the respiratory loop in conjunction with the ventilator's overall performance.
  • Flow Adaptability: Adjusts to different exhalation flows of patients.


Parameter Category Specific Parameters
Ventilation Modes

IPPV (CMV), IPPV assist (A/C), SIMV, SIMV ASB, CPAP ASB,

BIPAP (PCV +) (optional), BIPAP ASB (PCV + PS) (optional)

Patient Range Adults, pediatric patients
Ventilation Frequency 2–80 breaths/min
Inspiratory Time 0.2–10 seconds
Tidal Volume 0.05–2.0 L (BTPS)
Inspiratory Flow Rate 0–180 L/min
Inspiratory Pressure 0–100 mbar
PEEP/interm.PEEP 0–35 mbar
ASB (Airway Support Pressure) 0–35 mbar (relative to PEEP)
Flow Acceleration 5–200 mbar/s
Oxygen Concentration 21–100 vol.%
Trigger Sensitivity 1–15 L/min
Airway Pressure Measurement

Peak pressure, plateau pressure, mean airway

pressure, PEEP (0–100 mbar)

Minute Ventilation 0–100 L/min
Tidal Volume (BTPS) 0–4000 mL
Respiratory Rate 0–150 breaths/min
FiO₂ (Fraction of Inspired Oxygen) 15–100%
Respiratory Gas Temperature 18–51°C (with optional sensor)
Curve Display Airway pressure/time, flow/time
Inspiration-Expiration Ratio 11:1–1:150
Maximum Flow Rate (during pressure support/spontaneous breathing) 180 L/min
Valve Response Time ≤5 ms
Safety Valve Opening Pressure 100 bar
Built-in Battery Approximately 60 minutes (external battery up to 7 hours)

8413660 0–100 L/min Minute Ventilation Repetitive Exhalation Valve for Ventilator with Oxygen Concentration


Product Tags:

100 L/min Exhalation Valve

      

8413660 Ventilator Exhalation Valve

      

Oxygen Concentration Exhalation Valve

      
Wholesale 8413660 0–100 L/min Minute Ventilation Repetitive Exhalation Valve for Ventilator with Oxygen Concentration from china suppliers

8413660 0–100 L/min Minute Ventilation Repetitive Exhalation Valve for Ventilator with Oxygen Concentration Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ShenzhenYijiajie Electronic Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)